Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Glob Health Med ; 4(5): 294-295, 2022 Oct 31.
Artículo en Inglés | MEDLINE | ID: covidwho-2115794

RESUMEN

The duties of a clinical engineer (CE) during the coronavirus infection 2019 (COVID-19) pandemic were diverse. The original duties of a CE included operation and maintenance of life support equipment used for respiratory therapy, hemodialysis, and extracorporeal membrane oxygenation. The management of life support equipment is critical. The PB-840 ventilator is equipped with a heat sink system that dissipates internal heat through thermal conduction. Therefore, internal contamination is less likely to occur. The exhalation filter used in the PB- 840 can be used for up to 15 days. It can be used for long periods of time without maintenance, reducing the risk of infection. The PB-840 is a suitable device for patients with COVID-19. Its use in critically ill patients was determined to be a priority. Thus, use of an appropriate device for infection control requires a proper understanding of and familiarity with the device in question.

2.
ASAIO J ; 67(5): 511-516, 2021 05 01.
Artículo en Inglés | MEDLINE | ID: covidwho-1045803

RESUMEN

Patients with the coronavirus disease 2019 (COVID-19) sometimes develop refractory respiratory failure and may require venovenous extracorporeal membrane oxygenation (VV-ECMO). It is known that the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is sometimes present in the blood of COVID-19 patients. VV-ECMO is often used for several weeks, and plasma leaks can occur, albeit rarely. Hence, in terms of infection control, a concern is that SARS-CoV-2 may leak from the gas outlet port of the oxygenator during ECMO support of critically ill COVID-19 patients. The aim of this study was to clarify whether SARS-CoV-2 leaks from the oxygenator during ECMO support. Five patients with critical COVID-19 pneumonia were placed on VV-ECMO. Silicone-coated polypropylene membrane oxygenators were used in the ECMO circuits for these patients. SARS-CoV-2 ribonucleic acid (RNA) was measured by quantitative reverse transcription polymerase chain reaction in serum and at the gas outlet port of the ECMO circuit at the time of circuit replacement or liberation from ECMO. SARS-CoV-2 RNA was detected in the gas outlet port of the ECMO circuit for three of the five patients. None of the medical staff involved in the care of these five patients has been infected with COVID-19. In conclusion, SARS-CoV-2 could leak to the gas outlet port of the ECMO circuit through silicone-coated polypropylene membranes during ECMO support of critically ill COVID-19 patients.


Asunto(s)
COVID-19/terapia , Oxigenación por Membrana Extracorpórea/efectos adversos , SARS-CoV-2/aislamiento & purificación , COVID-19/complicaciones , Humanos , Estudios Prospectivos , ARN Viral/análisis , Insuficiencia Respiratoria/terapia
3.
J Clin Apher ; 36(3): 313-321, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: covidwho-978131

RESUMEN

OBJECTIVE: To evaluate the efficacy and safety of direct hemoperfusion using a polymyxin B-immobilized polystyrene column (PMX-DHP) in severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2)-positive pneumonia patients. METHODS: This study was a case series conducted at a designated infectious diseases hospital. Twelve SARS-CoV-2-positive patients with partial pressure of arterial oxygen/percentage of inspired oxygen (P/F) ratio < 300 were treated with PMX-DHP on two consecutive days each during hospitalization. We defined day 1 as the first day when PMX-DHP was performed. PMX-DHP efficacy was assessed on days 7 and 14 after the first treatment based on eight categories. Subsequently, improvement in P/F ratio and urinary biomarkers on days 4 and 8, malfunctions, and ventilator and extracorporeal membrane oxygenation avoidance rates were also evaluated. RESULTS: On day 14 after the first treatment, disease severity decreased in 58.3% of the patients. P/F ratio increased while urine ß2-microglobulin decreased on days 4 and 8. Cytokine measurement pre- and post-PMX-DHP revealed decreased levels of interleukin-6 and the factors involved in vascular endothelial injury, including vascular endothelial growth factor. Twenty-two PMX-DHPs were performed, of which seven and five PMX-DHPs led to increased inlet pressure and membrane coagulation, respectively. When the membranes coagulated, the circuitry needed to be reconfigured. Circuit problems were usually observed when D-dimer and fibrin degradation product levels were high before PMX-DHP. CONCLUSIONS: Future studies are expected to determine the therapeutic effect of PMX-DHP on COVID-19. Because of the relatively high risk of circuit coagulation, coagulation capacity should be assessed beforehand.


Asunto(s)
COVID-19/terapia , Hemoperfusión/instrumentación , Hemoperfusión/métodos , Polimixina B/química , Poliestirenos/química , Adulto , Anciano , Anciano de 80 o más Años , Arterias/metabolismo , Biomarcadores/orina , Análisis de los Gases de la Sangre , Citocinas/sangre , Endotelio Vascular/metabolismo , Femenino , Hospitalización , Humanos , Masculino , Persona de Mediana Edad , Oxígeno/metabolismo , Respiración Artificial , Estudios Retrospectivos , Riesgo , Microglobulina beta-2/orina
4.
Emerg Infect Dis ; 26(11): 2758-2761, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: covidwho-690917

RESUMEN

We report detection of severe acute respiratory syndrome coronavirus 2 RNA in hemodialysis effluent from a patient in Japan with coronavirus disease and prolonged inflammation. Healthcare workers should observe strict standard and contact precautions and use appropriate personal protective equipment when handling hemodialysis circuitry from patients with diagnosed coronavirus disease.


Asunto(s)
Betacoronavirus/aislamiento & purificación , Infecciones por Coronavirus/diagnóstico , Infección Hospitalaria/virología , Riñones Artificiales/virología , Neumonía Viral/diagnóstico , Diálisis Renal/instrumentación , Anciano , COVID-19 , Prueba de COVID-19 , Técnicas de Laboratorio Clínico , Infecciones por Coronavirus/virología , Contaminación de Equipos , Humanos , Japón , Fallo Renal Crónico/terapia , Fallo Renal Crónico/virología , Masculino , Pandemias , Neumonía Viral/virología , SARS-CoV-2
5.
Blood Purif ; 50(1): 129-131, 2021.
Artículo en Inglés | MEDLINE | ID: covidwho-596558

RESUMEN

The outbreak of coronavirus disease 2019 (COVID-19) is a global health threat. It is a respiratory disease, and acute kidney injury (AKI) is rare; however, if a patient develops severe AKI, renal replacement therapy (RRT) should be considered. Recently, we had a critically ill COVID-19 patient who developed severe AKI and needed continuous RRT (CRRT). To avoid the potential risk of infection from CRRT effluents, we measured severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) genetic material in the effluents by qRT-PCR, and low copy numbers of the viral genome were detected. Due to unstable hemodynamic status in critically ill patients, CRRT should be the first choice for severe AKI in COVID-19 patients. We suggest prevention of clinical infection and control during administration of RRT in the acute phase of COVID-19 patients with AKI or multiple organ failure.


Asunto(s)
Lesión Renal Aguda/etiología , Lesión Renal Aguda/terapia , COVID-19/complicaciones , COVID-19/terapia , Terapia de Reemplazo Renal Continuo , Terapia de Reemplazo Renal Continuo/métodos , Humanos , Intubación Intratraqueal , Masculino , Respiración Artificial , SARS-CoV-2/aislamiento & purificación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA